- Dielectron decay of Z(Version1, 200pb^-1)
- Trigger requirement
- ELECTRON_CENTRAL_18 for Z(CC) and Z(CP)
- PLUG_ELECTRON_20 for Z(PP)
- Z_NOTRACK will be used for the whole topology
- 66 < Mass < 116 mass window used
- Tight central electron selection
- Region = 0
- EmEt[i] > 25
- Fiducial = 1
- Abs(TrkZ0) < 60
- Hadem < 0.055+0.00045*En
- Iso4 < 4
- LshrTrk < 0.2
- StripChi2 < 10
- Abs(DeltaZ) < 3.0
- -3.0 < Charge*DeltaX < 1.5
- TrkAxSeg > 3 <- added in Version2
- TrkStSeg > 2 <- added in Version2
- EmEt <= 100 : electron_EP < 2.0 , TrkPt > 10
- EmEt > 100 : TrkPt > 25
- Loose central electron selection
- Region = 0
- EmEt[i] > 25
- Fiducial = 1
- Abs(TrkZ0) < 60
- Hadem < 0.055+0.00045*En
- Iso4 < 4
- TrkAxSeg > 3 <- added in Version2
- TrkStSeg > 2 <- added in Version2
- EmEt <= 100 : TrkPt > 10
- EmEt > 100 : TrkPt > 25
- plug electron selection
- Region = 0
- EmEt[i] > 25(for Z(PP)), 20(for Z(CP))
- 1.2 < Pes2dEta < 2.8
- Abs(TrkZ0) < 60
- Hadem < 0.05
- Iso4 < 4
- Pem3x3Chisq < 10
- Pes2dby9U > 0.65 <- added in Version2
- Pes2dby9V > 0.65 <- added in Version2
- For phoenix track : PhxMatch = 1, PhxTrkSiHits > 3, Abs(PhxTrkZ0) < 60
- Dielectron decay of Z(Version2, 350pb^-1)
- Dataset
- TopNtuple 5.3.3_nt version used
- Z_NOTRACK trigger path used
- Good run list v7
- Integrated Luminosity : 363.9pb^-1 without sil, 333.7pb^-1 with sil
- MC sample : ztop7i (3M events)
- 66 < Mass of dielectron < 116
-
Mass distribution(CC,CP,PP)
- CC: mean=90.89, width=2.45, # of event = 9337
- CP: mean=90.70, width=2.74, # of event = 13453
- PP: mean=90.39, width=2.83, # of event = 5529
-
Rapidity distribution(blue:CC,pink:CP,red:PP)
-
Acceptance distribution(blue:CC,pink:CP,red:PP)
-
pnx track efficiency in rapidity
-
pnx track efficiency in Eta
-
Isolation of central electron from Z(CC) - QCD bkg
-
Isolation of central electron from Z(CP) - QCD bkg
-
Isolation of plug electron from Z(CP) - QCD bkg
-
Isolation of pnx electron from Z(PP) - QCD bkg
-
Isolation of plug electron from Z(PP) - QCD bkg
-
dsigma/dy distribution
- Background rate for QCD
- In Z(CC) : 0.007021 +- 0.000596
- In Z(CP) : 0.013072 +- 0.000302(central),0.013072 +- 0.000302(plug)
- In Z(PP) : 0.021884 +- 0.002318(pnx) ,0.022577 +- 0.002140(plug)
- What to do
- get the electron efficiency in eta and plug in the efficiency
- get the trigger efficiency
- systematic study